MODEL S1585
BATTERY BACKUP PEDESTAL SUMP PUMP
PREINSTALLATION CHECKLIST
95 N. Oak St. • Kendallville, IN 46755 • 1-800-345-9422
NOTICE TO INSTALLER: Instructions must remain with installation.
Manufacturers of . . .
“Quality Products since 1866”
95 N. Oak St. • Kendallville, IN 46755
1-800-345-9422
FW0264
1008
Supersedes
0305
1. Inspect your pump. Occasionally, products are dam aged during shipment. If the unit or any of the parts are dam aged, contact your dealer
before us ing.
2. Read all the installation instructions regarding in stall ing and start up. Retain for future ref er ence.
1. Make sure there is a properly ground ed 115V re cep tacle avail-
able. Do not use primary pump cir cuit. The location must be within
6' of the control box and battery. The power supply for your DC
control system plugs directly into the 115V outlet. DO NOT USE
AN EX TEN SION CORD.
2. Make sure the 115V electrical supply circuit is equipped
with fuses or circuit breakers of prop er capacity.
3. DC emergency pumps are de signed for han dling clear water. Do
not use in septic tanks to pump ef u ent or sew age pits to pump
sewage.
4. Repair and service of your DC backup sys tem should be per formed
by an authorized service station.
5. The installation of DC automatic back up pumps re quires the use
of a variable level oat switch for operation. It is the responsibility
of the installing party, to ensure that the teth ered oat switch will
not hang up on the pump ap pa ra tus or pit pe cu li ari ties and is
secured so the pump will turn “on” and “off”. It is recommended
that the pit be 18" in diameter or larger to ac com mo date both a
pri ma ry and a DC backup pump.
SEE BELOW FOR LIST OF WARNINGS
1. Testing for Ground. As a safe ty mea sure each elec tri cal outlet
should be checked for ground using an Underwriters Laboratory
list ed cir cuit ana lyzer, which will indicate if the power, neu tral and
ground wires are correctly con nected to your out let. If they are
not, call a quali ed licensed electrician.
2. For your pro tec tion always dis con nect the pow er supply from its
power source before handling the com po nents of your DC back up
pump or the pri ma ry pump.
3. Installation and checking of elec tri cal cir cuits and hard ware should
be per formed by a quali ed, li censed electrician.
4. All elec tri cal and safety codes must be fol lowed in ad di tion to the
National Electrical Code and all applicable local codes.
5. It is the owner’s responsibility to check the bat tery
and bat tery connection at least once a month. Bat-
ter ies con tain acid and cau tion must be taken when
han dling.
6. Risk of electric shock - These pumps have not been investigated
for use in swimming pool areas.
7. According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and
birth defects or other reproductive harm.
SEE BELOW FOR LIST OF CAUTIONS
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - MODEL S1585

1© Copyright 2008. All rights reserved.MODEL S1585BATTERY BACKUP PEDESTAL SUMP PUMPPREINSTALLATION CHECKLIST95 N. Oak St. • Kendallville, IN 46755 • 1

Page 2 - Performance Characteristics

2© Copyright 2008. All rights reserved. 1. Remove all debris from pit before installation. 2. Use a deep cycle battery only. Refer to battery de

Page 3 - Figure 1.1

3© Copyright 2008. All rights reserved.PRIMARY PUMPMAIN DISCHARGELINE"OFF"HEIGHT"ON"HEIGHT"ADJUST" ON/OFF POSITIONS STOP

Page 4 - Figure 3.1

4© Copyright 2008. All rights reserved.BATTERYRED LEADTO POSITIVE(+)TO NEGATIVE(-)BLACK LEADSWITCHCUT AWAY OF SUMP PITRED LEADTO POSITIVE(+)MOTORCHARG

Page 5 - The Aquanot® Battery

5© Copyright 2008. All rights reserved. The charger automatically monitors and charges your battery. In the event of a power outage the pump will be

Page 6 - Carbon Monoxide Detectors

6© Copyright 2008. All rights reserved.Illustrated Parts Breakdown Whether you have an Aquanot® Battery Backup Sump Pump System, or a competitive bra

Page 7 - REPLACEMENT PARTS LIST FOR:

7© Copyright 2008. All rights reserved.21123456 78910912 (OPTIONAL)131415 RED16 BLACK1819171120(OPTIONAL)22REPLACEMENT PARTS LIST FOR:AQUANOT® S1585 C

Page 8 - Troubleshooting Guide

8© Copyright 2008. All rights reserved. Before servicing a pump, always shut off the main pow er breaker and then unplug the pump - making sure you a